Send Message
Home > Products > Inline EMI Filter >
Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A

Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A

power entry filter

emi emc filter

Place of Origin:

China

Brand Name:

YBX

Certification:

cUL, TUV, CQC, CE, ROHS

Model Number:

YB11B2-10A-Q

Contact Us

Request A Quote
Product Details
Item:
YB11B2-10A-Q
Rated Current:
1A-10A
Rated Voltage:
110V
Operating Frequency:
50/60HZ
Line To Line:
1450DVC
Port:
Shenzhen
Payment & Shipping Terms
Minimum Order Quantity
100pcs
Price
Negotiable
Packaging Details
56.5*28.5*22.5cm
Delivery Time
20-25 days
Payment Terms
T/T, L/C
Supply Ability
10000 Piece/Pieces per Month
Product Description

Inline EMI Filter 120, 250VAC YB11B2 Double Fuse Power Entry Module Filters

 

Technical Specification:

 

Item IEC Filter
Model IEC Filter YB-B
Transfer Function Low Pass
Package Type Surface Mount
Nominal Center Frequency 10K-30MHZ
Insertion Loss 60~90dB
Input Impedance 50Ω
Rated Voltage 115V/250V
Rated Current 1~10A
Environmental Temperature 40°C
Temperature Range 25 / 085 / 21
Operating Frequency 50/60HZ
Line to Line 1450VDC
Line to Ground 2250VDC
Maximum Leakage Current 250VAC/60HZ 0.8mA Max
MOQ 100pcs
Price USD1~9.8/Meter
Lead Time 5~15 weekday

 

Features:

 

1. Versions to 10A are available with fuse holder for one or two (5*20mm) fuses

 

2. (R5) types comply with the requirements of IEC/EN60601-1 for safety clearance, leakage current and hipot testing

 

3. There are a variety of parts and combinations to meet different customer's EMC tests

 

Typical Applications:

 

-- Portable electrical and electronic equipment

 

-- Medical equipment

 

-- Test and measurement equipment

 

-- Small and medium-sized machines and household equipment

 

 

Rule of Nomination:

 

YB   11    B1      -    10A   -    Q          ( R  5  G )          

           ¦        ¦                  ¦             ¦                ¦    ¦    ¦                                

    circuit   case     current  connection optional

 

B1: One Fuse

B2: Two Fuses

 

Tabulates:

Model No. Rated Current
@40°C
Terminal Options*

Bleeder resistor

(optional)


G
Leakage current 250V/50Hz Electrical Schematic Rated Voltage(V) Operating Frequency(Hz)
 
     
YB11B1-1A 1A Q S - - -

 

 

 

 

 

 

<0.8mA

Fig.1

 

 

 

 

 

 

115/250V

 

 

 

 

 

 

50/60Hz

YB11B1-2A 2A Q S - - - Fig.1
YB11B1-3A 3A Q S - - - Fig.1
YB11B1-4A 4A Q S - - - Fig.1
YB11B1-6A 6A Q S - - - Fig.1
YB11B1-8A 8A Q S - - - Fig.1
YB11B1-10A 10A Q S - - - Fig.1
YB11B2-1A 1A Q S - - - Fig.1
YB11B2-2A 2A Q S - - - Fig.1
YB11B2-3A 3A Q S - - - Fig.1
YB11B2-4A 4A Q S - - - Fig.1
YB11B2-6A 6A Q S - - - Fig.1
YB11B2-8A 8A Q S - - - Fig.1
YB11B2-10A 10A Q S - - - Fig.1

 

 

Medical type Tabulates:

Model No. Rated Current
@40°C
Terminal Options

Bleeder resistor

(optional)

Medical equipment
5

G
Leakage current 250V/50Hz Electrical Schematic Rated Voltage(V) Operating Frequency(Hz)
                              
     
YB11B1-1A-x(R5) 1A Q S - 1 5 -

 

 

 

 

 

<5μA

Fig.2

 

 

 

 

 

115/250V

 

 

 

 

 

50/60Hz

YB11B1-2A-x(R5) 2A Q S - 1 5 - Fig.2
YB11B1-3A-x(R5) 3A Q S - 1 5 - Fig.2
YB11B1-4A-x(R5) 4A Q S - 1 5 - Fig.2
YB11B1-6A-x(R5) 6A Q S - 1 5 - Fig.2
YB11B1-8A-x(R5) 8A Q S - 1 5 - Fig.2
YB11B1-10A-x(R5) 10A Q S - 1 5 - Fig.2
YB11B2-1A-x(R5) 1A Q S - 1 5 - Fig.2
YB11B2-2A-x(R5) 2A Q S - 1 5 - Fig.2
YB11B2-3A-x(R5) 3A Q S - 1 5 - Fig.2
YB11B2-4A-x(R5) 4A Q S - 1 5 - Fig.2
YB11B2-6A-x(R5) 6A Q S - 1 5 - Fig.2
YB11B2-8A-x(R5) 8A Q S - 1 5 - Fig.2
YB11B2-10A-x(R5) 10A Q S - 1 5 - Fig.2

 

 

Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 0*Q: Fast-on 6.35x0.8mm             Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 1  S: solder 4.0x0.8mm        Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 2 W: UL1015 18awg

 

Electrical schematic:

 

Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 3

                        Fig.1

 

 

 

Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 4

                        Fig.2                                                                                                                      

 

Mechanical Dimension(Unit: mm)

Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 5


 

Case A B C D E F G H I J K
B1 58 28 32.5 44 36 33.5 13 11 12.5 3.5 6.35*0.8
B2 58 28 32.5 44 36 33.5 13 11 12.5 3.5 6.35*0.8
Tolerances ±1 ±1 ±1 ±1 ±0.15 ±1 ±0.5 ±0.5 ±0.5 ±1 ±0.15


 

 

                   

Insertion loss table(In 50ohm system according IEC/CISPR No.17)         

 

                     Common mode                              -------- differential mode

 

                                    1A                                                                                     3A          

       Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 6                          Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 7                                                                                       

 

                                      6A                                                                                    8A                 

        Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 8                          Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 9                                                                                              

 

                                     10A                                                                        

         Yanbixin 120 250VAC Double Fuse Power Entry Filter YB11B2 Rated Current 1A-10A 10

                         

 

Send your inquiry directly to us

Privacy Policy China Good Quality EMI Power Filter Supplier. Copyright © 2019-2024 emipowerfilter.com . All Rights Reserved.