380V 440V Three Phase Rfi Filter Low Pass Noise With ROHS Certificate
Item | 3 Phase Emi Filter | Rated Voltage | 380V/440V |
---|---|---|---|
Rated Current | 10A, 20A,30A, 40A, 50A, 60A, 70A | Environmental Temp | 40°C |
Line To Line | 1450VDC | Line To Ground | 2250VDC Or 2000VAC |
Certificate | CUL ENEC ISO9001 CE ROHS | Flammability Corresponding To | UL 94V-0 |
High Light | 440V Three Phase Rfi Filter,380V Three Phase Rfi Filter,380V three phase emi filter |
380V 440V Three Phase Rfi Filter Low Pass Noise With ROHS Certificate
Manufacturer 380V 440V 3 Phase EMI Filter Power AC line Noise EMC Filter with screw
Technical Specification:
Item | 3 Phase EMI Filter |
Model | 3 Phase EMI Filter -YX81G series |
Transfer Function | Low Pass |
Package Type | Surface Mount |
Nominal Center Frequency | 10K-30MHZ |
Insertion Loss | 60~90dB |
Input Impedance | 50Ω |
Rated Voltage | 380V/440V |
Rated Current | 1A-100A |
Environmental Temperature | 40°C |
Temperature Range | 25 / 085 / 21 |
Operating Frequency | 50/60HZ |
Line to Line | 1450VDC |
Line to Ground | 2250VDC or 2000VAC |
Maximum Leakage Current | 115VAC/60HZ 1.4mA Max. 250VAC/60HZ 2.5mA Max |
MOQ | Negotiable |
Price |
Negotiable |
Lead Time | 15~25 weekday |
Features:
-- Protection against interference of voltage.
-- YX81 filters provide a broadband common and differential-mode attenuation performance, it still can be available when the interference is larger.
-- Customized products according to customer's requirements.
Typical Applications:
1. Single-phase power supplies, switch-mode power supplies
2. Small to medium-sized machines and household equipment
3. Portable electrical and electronic equipment
4. Test and measurement equipment
5. Safety tester
6. Automated optical inspection (AOI)
7. SMPS
8. Medical device (not body-coupled)
9. Portable electrical and electronic equipment
Rule of Nomination:
YB 81 G3 - 50A -
¦ ¦ ¦ ¦
circuit case current connection
Tabulates:
Model No. | Rated Current @40°C |
Terminal Options* |
Leakage current 440V/50Hz | Electrical Schematic |
Rated Voltage(V) | Operating Frequency(Hz) | ||||||||||||||||||||||||||||||
YX81G1-1A | 1A | Q | S | T | <1.0mA | Fig.1 | 250/440V | 50/60Hz | ||||||||||||||||||||||||||||
YX81G1-3A | 3A | Q | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G1-6A | 6A | Q | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G1-10A | 10A | Q | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G1-20A | 20A | Q | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G1-30A | 30A | - | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G2-30A | 30A | - | S | T | <2.0mA | Fig.1 | ||||||||||||||||||||||||||||||
YX81G2-40A | 40A | - | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G3-40A | 40A | - | S | T | <5.0mA | Fig.1 | ||||||||||||||||||||||||||||||
YX81G3-50A | 50A | - | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G3-60A | 60A | - | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G5-80A | 80A | - | S | T | <7.0mA | Fig.1 | ||||||||||||||||||||||||||||||
YX81G5-100A | 100A | - | S | T | Fig.1 | |||||||||||||||||||||||||||||||
YX81G6-200A | 200A | - | S | T | <10.0mA | Fig.1 |


Case | A | B | C | D | E | F | G | H | I | J | K | L | ||||||||||||||||||||||||||||
G1 | 72 | 65 | 39 | 75 | 85 | 35 | 22 | 45 | M4 | M4/M6 | ||||||||||||||||||||||||||||||
G2 | 98 | 80 | 40 | 95 | 105 | 50 | 20 | 4.5*6.5 | 50 | M4 | M4/M6 | |||||||||||||||||||||||||||||
G3 | 120 | 100 | 50 | 115 | 130 | 50 | 28 | 4*6 | 60 | M4 | M4/M6 | |||||||||||||||||||||||||||||
G5 | 150 | 105 | 60 | 120 | 135 | 55 | 35 | 4*6 | 90 | M6 | M8 | |||||||||||||||||||||||||||||
G6 | 260 | 170 | 100 | 196 | 220 | 85 | 65 | 8*12 | 172 | M8 | M10 | |||||||||||||||||||||||||||||
Tolerances | ±1 | ±1 | ±1 | ±0.15 | ±1 | ±0.5 | ±0.5 | ±0.15 | ±0.15 | ±0.15 | ||||||||||||||||||||||||||||||
Insertion loss table(In 50ohm system according IEC/CISPR No.17)
6/10A 20A
30A 40/50A
100/200A
The packing Specification:
CTN: 56.5*28.5*20.5CM 40PCS/CTN
N.W/PCS: 0.38KG
G.W/PCS: 0.39KG
The factory introduction:
The quality certifications:
Sample
Sample Fee: Negotiate
Sample Time: 3~5 days
Payment
---Payment terms: Western Union, D/P, T/T, L/C
---Please remember to leave the correct contact information for delivery.
Shipment
---Shipping terms: DHL, UPS, FedEx, TNT, EMS
---Port is Shenzhen or as requests.
You may also be interested in these:
![]() |
![]() |
![]() |
![]() |