Home ProductsAC Power Noise Filter

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation

Certification
China Shenzhen Yanbixin Technology Co., Ltd. certification
China Shenzhen Yanbixin Technology Co., Ltd. certification
Customer Reviews
Well received the products, all of them are good, they have excellent quality, when you have any questions, they always can give you a quick response, thank you.

—— Steven

Our products are customized, so we have many technical things need to confirm, first, I though they won't get back to me, but they provide the best solutions for all of them, I appreciate, good company and best service!

—— Kathleen

I have placed a urgent order to them, after they received it, they try their best to delivery the goods to me within 15 days, I really admired, thanks.

—— Louis

Excellent product, excellent team, we have worked together for two years, the product failure rate is very low, saving us a large part of the after-sales cost

—— Karla

I'm Online Chat Now

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation
Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation

Large Image :  Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation

Product Details:
Place of Origin: China
Brand Name: YBX
Certification: cUL, TUV, CQC, CE, ROHS
Model Number: YB43D4-3A-Q
Payment & Shipping Terms:
Minimum Order Quantity: 50pcs
Price: Negotiable
Packaging Details: 56.5*28.5*22.5cm
Delivery Time: 20-25 days
Payment Terms: T/T, L/C
Supply Ability: 10000 Piece/Pieces per Month Ac 220V General Purpose Noise Filter

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation

Description
Item: YB43D4-3A-Q Rated Current: 1A-20A
Case: Metal Case Brand: YBX
Certificate: ISO9001 CUL TUV CQC CE ROHS Port: SHENZHEN
High Light:

ac power line filter

,

ac power supply filter

3A 120V 250V AC Medical EMC EMI Noise Filter For Building Automation

 

Technical Specification:

Item Power line Filter
Model Power line Filter YB-D/F
Transfer Function Low Pass
Package Type Surface Mount
Nominal Center Frequency 10K-30MHZ
Insertion Loss 60~90dB
Input Impedance 50Ω
Rated Voltage 115V/250V
Rated Current 1~50A
Environmental Temperature 40°C
Temperature Range 25 / 085 / 21
Operating Frequency 50/60HZ
Line to Line 1450VDC
Line to Ground 2250VDC
Maximum Leakage Current 250VAC/60HZ 0.8mA Max
MOQ 50pcs
Price USD3~28.8/Meter
Lead Time 5~15 weekday

 

Features:

 

-- Using multi-stage filter circuit, with excellent common mode and differential mode noise suppression, general purpose power line filter with fast-on/stud/wire terminals

 

-- Standard filters are a practical solution, which can helping you to pass EMI system test in a short time

 

-- There are a variety of parts and combinations to meet different customer's EMC tests.

 

-- Customized products according to customer's requirements.

 

Typical Applications:

 

-- Electrical and electronic equipment

 

-- Medical equipment

 

-- Building automation

 

-- Office automation and datacom equipment

 

Rule of Nomination:

 

YB    43    D3   -   10A    -     Q            (  5  )

            ¦        ¦               ¦              ¦                   ¦ ¦

     circuit  case     current connection optional

 

Tabulates:

Model No. Rated Current
@40°C
Terminal Options* Leakage current 250V/50Hz Electrical Schematic Rated Voltage(V) Operating Frequency(Hz)
 
     
YB43D3-1A 1A Q S W

 

 

 

 

 

 

<1.0mA

Fig.1

 

 

 

 

 

 

115/250V

 

 

 

 

 

 

50/60Hz

YB43D3-2A 2A Q S W Fig.1
YB43D4-3A 3A Q S W Fig.1
YB43D4-4A 4A Q S W Fig.1
YB43D4-6A 6A Q S W Fig.1
YB43D5-8A 8A Q S W Fig.1
YB43D5-10A 10A Q S W Fig.1
YB43D5-15A 15A Q S W Fig.1
YB43D6-10A 10A Q S W Fig.1
YB43D6-15A 15A Q S - Fig.1
YB43F2-20A 20A Q S T Fig.1
YB43F2-25A 25A - S T Fig.1
YB43F3-30A 30A - S T Fig.1

 

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 0*Q: Fast-on 6.35x0.8mm            Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 1  S: Screw lug           Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 2 W: UL1015 18awg

 

Electrical schematic:

 

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 3

                                        Fig.1

 

Mechanical Dimension(Unit: mm)

 

Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 4 


 

Case D3 D4 D5 D6 F2 F3 Tolerances
A 63 63 73 94 98 150 ±1
B 51 51 56 55 80 105 ±1
C 29 38 45 45 41 60 ±1
D 75 75 87 104 95 120 ±0.15
E 85 85 98 118 50 80 ±1
F 25 27 30 30 50 60 ±0.5
G 10 15.5 16 15 24 35 ±0.5
H 5 4.5 4.5 4.5*6 4.2 4*6 ±0.15
I         4.2*6.2 4*6 ±0.15
J         M4/M6 M4/M6  
K 6.3*0.8 6.3*0.8 6.3*0.8 6.3*0.8 M4 M4 ±0.15
L         50 60 ±2

 

 

 

Insertion loss table(In 50ohm system according IEC/CISPR No.17)

                                 Common mode                            -------- differential mode

 

                                   1A                                                                                                      

     Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 5                                 

 

                                 10A                                                                                  15A

    Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 6                          Medical AC Power Noise Filter / AC Input EMI Filter For Building Automation 7            

 

 

 

 

Contact Details
Shenzhen Yanbixin Technology Co., Ltd.

Contact Person: Alisa

Tel: +8618118799639

Send your inquiry directly to us (0 / 3000)