Double Fuse 220V 10A IEC Inlet Plug In RFI Filter For Medical Equipment
Material | Harware | Rated Voltage Max | 250VAC,50/60Hz |
---|---|---|---|
Operating Frequency | DC To 400Hz | Rated Currents | 1~10A@40°C |
Hipot Rating | L-N 1450VDC L-N 250VDC(with Lamp) L/N-G 2000VAC/2250VDC L/N-G 4000VAC(R5 Type) L-N 250VDC(with Lamp) L/N-G 2000VAC/2250VDC L/N-G 4000VAC(R5 Type) L-N 1450VDC L-N 250VDC(with Lamp) L/N-G 2000VAC/2250VDC | Inrush Current | 72A |
Protection Level | IP40 According To IEC 60529 | Climatic Category | -25°C~+100°C(25/100/21) |
Design Corresponding To | UL1283, CSA C22.2 No.8, IEC/EN 60939, CQC GB 15288/GB 15287-2008 | Flammability Corresponding To | UL 94V-0 |
High Light | 10A Plug In RFI Filter,220V Plug In RFI Filter,YB11C2-10A-Q |
Double Fuse 220V 10A IEC Inlet Plug In RFI Filter For Medical Equipment
IEC inlet filters YB-C series:
- Rated currents up to 10A
- Single or dural-fuse holder
- 2-pole socket switch
- Optional medical version(R5 type)
- Compact design with optimal shielding
- Approvals:
Electrical schematic:
Standard type
R5 type
Product Features:
- Screw-on mounting from the front side
- (R5) types comply with the requirements of IEC/EN60601-1 for safety clearance, leakage current, and hi-pot testing.
- There are a variety of parts and combinations to meet different customer's EMC tests
- Customized products according to customer's requirements
Typical Applications:
Rule of Nomination:
YB 12 C2 -10A -Q (R 5 G) C1---Single fuse
| | | | | | |
circuit case current output option option option C2---Dual fuse
Tabulates:
Model No. | Rated Current @40°C |
Terminal Options | Bleeder resistor(optional) | Ground inductance G(optional) |
Leakage current 250V/50Hz |
Electrical Schematic |
Rated Voltage(V) | Operating Frequency(Hz) | |||||||||||||||||||||||||||||||||||||
|
|
![]()
|
|||||||||||||||||||||||||||||||||||||||||||
YB12C1-1A | 1A | Q | S | - | - | - | <0.8mA | Fig.1 | 115/250V | 50/60Hz | |||||||||||||||||||||||||||||||||||
YB12C1-3A | 3A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C1-6A | 6A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C1-8A | 8A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C1-10A | 10A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C2-1A | 1A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C2-3A | 3A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C2-6A | 6A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C2-8A | 8A | Q | S | - | - | - | Fig.1 | ||||||||||||||||||||||||||||||||||||||
YB12C2-10A | 10A | Q | S | - | - | - | Fig.1 |
Medical Type:
Model No. | Rated Current @40°C |
Terminal Options |
Bleeder resistor(optional)R(MΩ) | Medical equipment 5 |
Ground inductance G(optional) |
Leakage current 250V/50Hz | Electrical Schematic |
Rated Voltage(V) | Operating Frequency(Hz) |
|||||||||||||||||||||||||||||||||||||||
|
|
![]()
|
||||||||||||||||||||||||||||||||||||||||||||||
YB12C2-1A-x(R5) | 1A | Q | S | - | 1 | 5 | - | <5μA | Fig.2 | 115/250V | 50/60Hz | |||||||||||||||||||||||||||||||||||||
YB12C2-3A-x(R5) | 3A | Q | S | - | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB12C2-6A-x(R5) | 6A | Q | S | - | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB12C2-8A-x(R5) | 8A | Q | S | - | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB12C2-10A-x(R5) | 10A | Q | S | - | 1 | 5 | - | Fig.2 |
Mechanical Dimension:(Unit: mm)
C Case
Case | C1 | C2 | Tolerances |
|||||||||||
A | 62.0 | 62.0 | ±1 | |||||||||||
B | 61.0 | 61.0 | ±1 | |||||||||||
C | 29.5 | 29.5 | ±1 | |||||||||||
D | 50.0 | 50.0 | ±1 | |||||||||||
E | 40.0 | 40.0 | ±0.15 | |||||||||||
F | 64.8 | 64.8 | ±1 | |||||||||||
G | 11.0 | 11.0 | ±0.5 | |||||||||||
H | 11.0 | 11.0 | ±0.5 | |||||||||||
I | 17.0 | 17.0 | ±0.5 | |||||||||||
J | 3.5 | 3.5 | ±0.1 | |||||||||||
K | 4.0 | 4.0 | ±0.1 | |||||||||||
Insertion loss table(In 50ohm system according to IEC/CISPR No.17):
3A 6A 10A
Sample
-- Sample Fee: Negotiate
-- Sample Time: 3~5 days
Payment
---Payment terms: Western Union, D/P, T/T,L/C
---Please remember to leave the correct contact information for delivery.
Packaging
Power Line Filter: CTN/300pcs
N/G W.: 13.5/14.3KG
Measures:0.565*0.285*0.225m
Shipment
---Shipping terms: DHL, UPS, FEDEX, TNT, EMS
---Port is Shenzhen or as requests.
Factory Pictures:
Our patents:
Our certification:
Our Advantages:
- National high-tech enterprises, brand assurance, reliable quality, after years of efforts of the company's personnel, products successively obtained the cUL, TUV, CQC, CE, ROSH certifications.
- We have a professional R&D team; our aim is we won't let customers spend any extra money!
- We cooperate with top scientific research laboratories to provide free EMC rectification technical support, samples; and free conduction test.
- Automation technology, scale production, great price, excellent, service, fast delivery! We supply free samples and free replacement.
- After-sale: within three months, free maintenance within six years, life-long maintenance!
GIVE US A CHANCE TO COOPERATE
WITH YOU!
Relevant product: