Place of Origin:
China
Brand Name:
YBX
Certification:
cUL,TUV,CQC,CE,ROHS,CB,ENEC,REACH
Model Number:
YB11A2-10A-Q
Contact Us
EMI Noise Filter IEC 320 Socket Plug In Filter 250VAC For Power Equipment
Technical Specification of EMI filter:
Item | Socket Emi Power Filter |
Model | Socket Emi Power Filter YB-A |
Transfer Function | Low Pass |
Package Type | Surface Mount |
Nominal Center Frequency | 10K-30MHZ |
Insertion Loss | 60~90dB |
Input Impedance | 50Ω |
Rated Voltage | 115VAC 250VAC |
Rated Current | 1A 3A 6A 10A |
Environmental Temperature | 40°C |
Temperature Range | 25 / 085 / 21 |
Operating Frequency | 50/60HZ |
Line to Line | 1450VDC |
Line to Ground | 2250VDC |
Maximum Leakage Current | 115VAC/50HZ 0.3uA Max |
MOQ | 500pcs |
Price | USD1.39~1.85/Meter |
Lead Time | 5~15 weekday |
Power Entry Module EMI Power Filter Inlet 1-10A Emi Filter with Medical Type
Features Of EMI filter:
-- Excellent performance/compact structure
-- Screw-on version from front rear side
-- Optional medical versions((R5) type)
-- Quick connect(6.35*0.8mm), solder or wire
-- High performance and high attenuation power filters with IEC 320 socket
-- (R5) types comply with the requirements of IEC/EN60601-1 for safety clearance, leakage current and high hipot testing.
-- There are a variety of parts and combinations to meet different customer's EMC tests.
-- Customized products according to customer's requirements
Typical Applications Of EMI filter:
-- Specially designed for LCD and PDP TV, medical applications,general electrical appliances.
-- Medical equipment
-- Test and measurement equipment
-- Small and medium-sized machines and household equipment
-- Single-phase power supplies, switch-mode power supplies
Rule of Nomination Of EMI filter:
YB 11 A1 - 10A - Q/S ( R 5 G )
¦ ¦ ¦ ¦ ¦ ¦ ¦
circuit case current Q:quick-on optional
S:tin solder
Electrical schematic Of EMI filter:
Standard type Medical(R5) type
Fig.1 Fig.2
Mechanical Dimension(Unit: mm) Of EMI filter:
Case | A | B | C | D | E | F | G | H | I | J | K | L | M | N |
A1 | 58 | 28.5 | 21 | 50 | 40 | 22.4 | 12.7 | 11.8 | 13.5 | 3.2 | 6.35*0.8 | |||
A2 | 58 | 28.5 | 21 | 52 | 40 | 25 | 12.7 | 11.8 | 13.5 | 3.2 | 6.35*0.8 | |||
Tolerances |
±1 | ±1 | ±1 | ±1 | ±0.15 | ±1 | ±0.5 | ±0.5 | ±0.5 | ±1 | ±0.15 |
Tabulates Of EMI filter:
Rated Current @40°C |
Terminal Options* | Bleeder resistor (optional) | G (optional) | Leakage current 250V/50Hz | Electrical Schematic | Rated Voltage | Operating Frequency (Hz) | |||
Model No. | ||||||||||
YB11A1-1A | 1A | Q | S | W | - | - |
<0.8mA |
Fig.1 |
115/250V |
50/60Hz |
YB11A1-2A | 2A | Q | S | W | - | - | Fig.1 | |||
YB11A1-3A | 3A | Q | S | W | - | - | Fig.1 | |||
YB11A1-4A | 4A | Q | S | W | - | - | Fig.1 | |||
YB11A1-6A | 6A | Q | S | W | - | - | Fig.1 | |||
YB11A1-8A | 8A | Q | S | W | - | - | Fig.1 | |||
YB11A1-10A | 10A | Q | S | W | - | - | Fig.1 | |||
YB11A1-15A | 15A | Q | S | W | - | - | Fig.1 | |||
YB11A2-1A | 1A | Q | S | W | - | - | Fig.1 | |||
YB11A2-2A | 2A | Q | S | W | - | - | Fig.1 | |||
YB11A2-3A | 3A | Q | S | W | - | - | Fig.1 | |||
YB11A2-4A | 4A | Q | S | W | - | - | Fig.1 | |||
YB11A2-6A | 6A | Q | S | W | - | - | Fig.1 | |||
YB11A2-8A | 8A | Q | S | W | - | - | Fig.1 | |||
YB11A2-10A | 10A | Q | S | W | - | - | Fig.1 | |||
YB11A2-15A | 15A | Q | S | W | - | - | Fig.1 |
Medical Products Model Lists:
Rated Current @40°C |
Terminal Options |
Bleeder resistor(optional) R(MΩ) |
Medical equipment 5 |
G |
Leakage current 250V/50Hz | Electrical Schematic |
Rated Voltage(V) | Operating Frequency(Hz) |
||||||||||||||||||||||||||||||||||||||||
Model No. | ||||||||||||||||||||||||||||||||||||||||||||||||
YB11A1-1A-x(R5) | 1A | Q | S | W | 1 | 5 | - | <5μA | Fig.2 | 115/250V | 50/60Hz | |||||||||||||||||||||||||||||||||||||
YB11A1-2A-x(R6) | 2A | Q | S | W | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB11A1-3A-x(R5) | 3A | Q | S | W | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB11A1-4A-x(R5) | 4A | Q | S | W | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB11A1-6A-x(R5) | 6A | Q | S | W | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB11A1-8A-x(R6) | 8A | Q | S | W | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB11A1-10A-x(R5) | 10A | Q | S | W | 1 | 5 | - | Fig.2 | ||||||||||||||||||||||||||||||||||||||||
YB11A1-15A-X(R5)** | 15A | Q | S | W | 1 | 5 | - | Fig.2 |
W: Wire UL1015 18AWG
Insertion loss table(In 50ohm system according to IEC/CISPR No.17) Of EMI filter:
Common mode -------- differential mode
Factory Environment:
Certifications and Patents:
FAQ:
Q: What are the main products of your company?
A: IEC inlet socket EMI filter, single-phase filter, Three-phase RFI filter, house appliance noise filter, Medical equipment filter, inver/converter EMC filter, etc.
Q: How is the quality of your product?
A: All our products have pass UL, TUV, CE, ROHS, ISO9001 approval. which ensures the quality of the product.
Q: What are services available for pre-batch orders?
A: Free samples and EMC technical rectification services are supplied before-sale
Q: What are services available after-sale?
A: Free replacement within three-month, free maintenance within six-year, life-long maintenance.
Q: What facilities do you have?
A: We have our own laboratory and production base to establish large-scale production.
Q: What the delivery time for 1000pcs of EMI FILTER?
A: Normally 15-20 days, but we can coordinate for a better delivery time if it is urgent.
Packaging
Power Line Filter: CTN/300pcs
N/G W.: 10.2/11.34KG
Measures: 56.5*28.5*20.5(cm)
Shipment
---Shipping terms: DHL, UPS, FEDEX, TNT, EMS
---Port is Shenzhen or as requests.
PLEASE GIVE US A CHANCE TO COOPERATE
WITH YOU!
Send your inquiry directly to us